PLUMBING Routine Inspection Schedule

MyHandyHomeHelp.com

Plumbing System Inspection* Items

  • Report
    • location of water meter
    • location of homeowners main water supply shutoff valve
    • static water pressure
  • Report as deficiencies:
    • presence of active leaks
    • water pressure exceeding 80 PSI
    • absence of fixture shutoff valves
    • absence of back-flow devices, anti-siphon devices, or air gaps at the flow end of
    • water supply pipes and waste pipes
    • the installation and termination of the vent system
    • the performance of fixtures and faucets not connected to an appliance
    • fixture drain performance
    • orientation of hot and cold faucets
    • installed mechanical drain stops
    • condition of commodes, fixtures, showers, tubs, and enclosures
    • the condition of the gas distribution system
  • Water heaters.
    • Report:
      • the energy source
      • capacity of the units
    • Report as Deficient:
      • inoperative units
      • leaking or corroded fittings or tanks
      • damaged or missing components
      • the absence of a cold water shutoff valve
      • if applicable, the absence of a pan or a pan drain system that does not terminate over a waste receptor or to the exterior of the building above the ground surface
      • inappropriate locations
      • the lack of protection from physical damage
      • burners, burner ignition devices or heating elements, switches, or thermostats that are not a minimum of 18 inches above the lowest garage floor elevation, unless the unit is listed for garage floor installation;
      • the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish
      • when applicable; a floored passageway and service platform that would allow access for equipment inspection, service, repair or replacement
      • the absence of or visible deficiencies in the temperature and pressure relief valve and discharge piping
    • Requirements for electric units:
      • deficiencies in:
        • performance of heating elements
      • Requirements for gas units:
        • Deficiencies in:
          • gas leaks in water heater
          • combustion and dilution air
          • vent pipe, draft hood, draft, proximity to combustibles, and vent termination point and clearances
  • Hydro-massage therapy equipment
    • Report as deficient:
      • inoperative units
      • the presence of active leaks
      • deficiencies in components and performance
      • missing and damaged components
      • the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish
      • the absence or failure of operation of ground-fault circuit interrupter protection devices
  • Gas distribution systems
    • Report:
      • location of gas meter
      • visible material used for gas distribution system
    • Report as deficient:
      • noticeable gas leaks
      • the absence of a gas shutoff valve within six feet of the appliance
      • the absence of a gas appliance connector or one that exceeds six feet in length
      • gas appliance connectors that are concealed within or extended through walls, floors, partitions, ceilings or appliance housings
      • deficiencies in:
        • gas shutoff valves
        • access to a gas shutoff valves that prohibits full operation
        • gas appliance connector materials
        • the condition and type of gas distribution lines and fittings
        • lack of visible bonding on gas distribution system
        • lack of visible sediment traps

*Note: The inspection observes only readily accessible and visible components and conditions. Latent, obscured and/or reasonably inaccessible components and materials may prevent inspection of those items.