PLUMBING Routine Inspection Schedule
MyHandyHomeHelp.com
Plumbing System Inspection* Items
- Report
- location of water meter
- location of homeowners main water supply shutoff valve
- static water pressure
- Report as deficiencies:
- presence of active leaks
- water pressure exceeding 80 PSI
- absence of fixture shutoff valves
- absence of back-flow devices, anti-siphon devices, or air gaps at the flow end of
- water supply pipes and waste pipes
- the installation and termination of the vent system
- the performance of fixtures and faucets not connected to an appliance
- fixture drain performance
- orientation of hot and cold faucets
- installed mechanical drain stops
- condition of commodes, fixtures, showers, tubs, and enclosures
- the condition of the gas distribution system
- Water heaters.
- Report:
- the energy source
- capacity of the units
- Report as Deficient:
- inoperative units
- leaking or corroded fittings or tanks
- damaged or missing components
- the absence of a cold water shutoff valve
- if applicable, the absence of a pan or a pan drain system that does not terminate over a waste receptor or to the exterior of the building above the ground surface
- inappropriate locations
- the lack of protection from physical damage
- burners, burner ignition devices or heating elements, switches, or thermostats that are not a minimum of 18 inches above the lowest garage floor elevation, unless the unit is listed for garage floor installation;
- the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish
- when applicable; a floored passageway and service platform that would allow access for equipment inspection, service, repair or replacement
- the absence of or visible deficiencies in the temperature and pressure relief valve and discharge piping
- Requirements for electric units:
- deficiencies in:
- performance of heating elements
- Requirements for gas units:
- Deficiencies in:
- gas leaks in water heater
- combustion and dilution air
- vent pipe, draft hood, draft, proximity to combustibles, and vent termination point and clearances
- Deficiencies in:
- deficiencies in:
- Report:
- Hydro-massage therapy equipment
- Report as deficient:
- inoperative units
- the presence of active leaks
- deficiencies in components and performance
- missing and damaged components
- the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing permanent construction or building finish
- the absence or failure of operation of ground-fault circuit interrupter protection devices
- Report as deficient:
- Gas distribution systems
- Report:
- location of gas meter
- visible material used for gas distribution system
- Report as deficient:
- noticeable gas leaks
- the absence of a gas shutoff valve within six feet of the appliance
- the absence of a gas appliance connector or one that exceeds six feet in length
- gas appliance connectors that are concealed within or extended through walls, floors, partitions, ceilings or appliance housings
- deficiencies in:
- gas shutoff valves
- access to a gas shutoff valves that prohibits full operation
- gas appliance connector materials
- the condition and type of gas distribution lines and fittings
- lack of visible bonding on gas distribution system
- lack of visible sediment traps
- Report:
*Note: The inspection observes only readily accessible and visible components and conditions. Latent, obscured and/or reasonably inaccessible components and materials may prevent inspection of those items.